Key Concerns About Low‑Voltage Motors: What Practitioners Ask Most Often
Nov. 25, 2025
1. Why Am I Seeing a Very Low Amp Draw on My Low‑Voltage Motor When Using a VFD?
One of the most frequent issues reported by users involves unexpectedly low current readings on one phase when low voltage motors are driven by variable‑frequency drives (VFDs). For example, some operators report just 1 to 2 amps per leg, far below what they would expect based on the motor’s nameplate. This can lead to confusion about whether the motor is working properly or if there is a wiring or load issue.
What’s Really Going On
Voltage imbalance: If the supply voltage entering the VFD is unbalanced across the three phases, it can distort how current is drawn under load. Imbalanced voltage may lead to uneven currents, especially in lightly loaded systems.
No input reactor or filters: Without line reactors, input filtering, or proper grounding, the VFD may not be smoothing the waveform effectively. This can suppress expected current draw or distort readings.
Measurement error: Many standard current clamps and meters struggle to accurately read PWM (pulse-width‑modulated) waveforms generated by VFDs, leading to misleading low amplitude readings.
Light actual load: In some setups the motor may genuinely be lightly loaded, drawing less current because it is not required to produce much torque.
What You Can Do
Check and correct any input voltage imbalance.
Use line reactors or input filters to stabilize your drive input and reduce harmonic distortion.
Use a true RMS meter or scope with a low-pass filter to measure actual current waveforms.
Confirm motor load: disconnect the driven load (if safe) and run the motor lightly to see whether current rises in proportion.
2. Why Does My VFD Trip for Overcurrent When Driving a Low‑Voltage Motor?
Another common concern is that VFDs sometimes fault with overcurrent alarms very quickly, even when powering a seemingly small or lightly loaded motor. This frustrates many users because they expect nominal motors to run smoothly under modern drives.
Possible Underlying Causes
Incorrect VFD parameter setup: If the drive’s overcurrent limit is set too low or doesn’t align with the motor’s true full-load current, the VFD may trigger faults under brief spikes.
Motor not “inverter rated”: General-purpose low-voltage motors may not tolerate the high-frequency switching stress of a VFD, especially if the insulation or winding design is not robust.
Cable or connection issues: Loose or undersized wires between the VFD and the motor can create voltage drops or transient spikes that lead to overcurrent detection.
Startup or deceleration dynamics: Aggressive acceleration or deceleration ramps without proper configuration can push the motor current beyond safe limits.
How to Mitigate It
Double-check and configure the VFD’s current limits, overload thresholds, and acceleration/deceleration parameters to match your motor’s nominal ratings.
Consider using motors designed for inverter service or “drive‑duty” motors with better insulation and thermal characteristics.
Ensure proper cable sizing and check all terminations.
Use soft-start ramps or current‑limiting features on the VFD to reduce inrush and transient peaks.
3. Why Do Low‑Voltage Motors and VFD Systems Require Frequent Wiring or Motor Replacements?
Some users report they are constantly replacing motors or the wiring between their VFDs and motors. In one shared case, a plant was replacing motor cables many times over, even though the drives themselves remained intact.
What Is Causing These Recurring Failures
Voltage spikes on long cable runs: When motor cables are long, the PWM pulses from the VFD can stack up, generating very high peak voltages that stress motor insulation.
Lack of protective filtering: Without dv/dt filters or sine‑wave filters on the VFD output, the motor sees harsh voltage transitions that slowly degrade the insulation.
Grounding or shielding issues: Poorly grounded or unshielded cables can allow electrical noise and stray currents to damage windings or bearings.
Motor not matched to duty cycle: Motors that are not rated for the switching environment may overheat or sustain damage faster under continuous or heavy VFD use.
Recommended Practices
Use dv/dt or sine‑wave filters at the drive output, particularly if cable runs are long.
Select low‑voltage motors that are specifically rated for VFD or inverter use, with insulation systems designed to handle switching stress.
Use shielded drive cables and properly ground the system.
Review the duty cycle and operating profile of your motors to ensure they are appropriate for the application.
4. What Causes Under‑Voltage or “Low Voltage” Faults in the VFD When Powering Low‑Voltage Motors?
Low-voltage fault messages in VFDs are a frequent source of confusion, especially when everything seems wired correctly and the motor is nominally compatible.
Typical Reasons for These Faults
Insufficient input voltage to the drive: If the AC supply is unstable, unbalanced, or sagging under load, the DC bus in the VFD might fall below the required threshold, triggering an undervoltage error.
Incorrect drive settings: If nameplate voltage or motor parameters are misconfigured in the VFD, it may misinterpret valid conditions as fault conditions.
Excessive load or torque demand: If the driven load suddenly demands more torque than expected (for example during startup), the current draw can pull down system voltage.
Aging or faulty components: Problems in the VFD input section, like failing capacitors on the DC bus, may reduce the available bus voltage over time, making low-voltage faults more likely.
What Can Be Done to Prevent It
Monitor and stabilize your input power supply, ensuring phase balance and sufficient capacity.
Correctly configure VFD parameters to match the motor nameplate exactly — incorrect voltage or frequency settings can lead to under‑voltage trips.
Use soft start / ramp up features or limit torque demand during start-up to reduce sudden voltage drops.
Periodically inspect and maintain the VFD, replacing aging components in the DC bus or rectifier as needed.
5. Can Insulation Resistance Testing Damage a VFD or Low‑Voltage Motor System?
Some users have reported catastrophic failures after using insulation resistance (megger) testers on motor cables that are connected to VFDs. They wonder whether such testing is safe.
Why This Is Risky
Insulation testers apply high DC voltages (often several hundred to a few thousand volts) by design. If a motor cable or winding is still connected to a drive, that test voltage can travel into the VFD.
The drive’s semiconductor devices (IGBTs or MOSFETs) are not designed to handle sudden high-voltage impulses from megger tests, and they can be destroyed by such stress.
Some say that applying a megger while the drive is disconnected but the motor remains connected can still damage components: the transient may feed back into the drive’s DC link or gate circuits.
How to Test Safely
Disconnect the motor from the VFD before performing insulation resistance tests. This isolates the drive and prevents damage.
If you must test, use a portable tester with limited voltage, or a specially designed test set that is compatible with inverter-rated motors.
For condition monitoring, consider partial discharge testing or surge comparison testing rather than classical megger tests. These methods are safer for drive‑connected motors and provide more relevant information about insulation health.
Final Thoughts
Low-voltage motors controlled by VFDs are ubiquitous in modern industrial applications, but they bring their own set of challenges. The five questions above reflect real-world pain points: undercurrent readings, overcurrent faults, repeated motor failures, low-voltage drive faults, and the risks of insulation testing.
To maximize reliability and performance, you should:
Use measurement tools suited for VFD environments.
Choose inverter‑rated motors and properly matched drives.
Implement protective measures such as filters, correct cabling, and grounding.
Monitor system health with diagnostics tailored for inverter-driven systems.
Follow safe testing practices that protect both the motor and the drive.
By understanding these common issues and taking proactive steps, you can get the full benefit of low-voltage motors while avoiding the frustration and downtime that often accompany them.